The Most Economically Sound Option for Data Center Expansion

Silver Linings are individually powered and cooled cabinets into which you can place servers and complementary support equipment to accommodate your current IT capacity needs while creating an economical platform for future growth.

Universal Equipment Storage

Universal Equipment Storage

Racking can hold any brand of server and/or other types of IT equipment as needed. Standard racks are cabinet-style enclosures (4 @ 24”/180U) or 4-post (5@19”/225U) open-face style.
- Up to 250U custom configurations are available.
- “Half” Rafts are also available.
- Permits creating server density to match user need, and mixing and matching brands and types of IT equipment.

Horizontally Movable Equipment Base

Horizontally Movable Equipment Base

Racks can easily be moved from left to right side of Raft, allowing two-sided service access while maintaining maximum rack depth.

High Strength Steel Base

High Strength Steel Base

Supports full equipment loading. Permits Rafts to be lifted and maneuvered with forks as easily as a standard loaded skid. Space for water containment is beneath the flooring and below all electronic equipment.

Coolant Pipes beneath Steel Flooring

Coolant Pipes beneath Steel Flooring

Cooling liquids contained within a metal barrier beneath electronic equipment, preventing accidental contamination and enhancing operational safety.

Structural Square-Tube Steel Skeleton

Structural Square-Tube Steel Skeleton

Strength and structural rigidity whether Rafts are housed in a container, a custom external shelter or a data center building. Aluminum option available.

Cooling System: Multi-fan Panel

Cooling System: Multi-fan Panel

Multiple high efficiency, low energy-use fans are programmed to respond automatically to changes in the Raft’s cooling requirements and resistance to air flow. Initiates “push” phase of cooling method.
» Read more

Cooling System: Proprietary Heat Exchanger Design

Cooling System: Proprietary Heat Exchanger Design

Patented configuration of cooling core components dramatically increases heat removal capability, eliminating up to 50% more heat with no increase in energy usage.
» Read more

Cooling System: Fan-driven Return Ducts

Cooling System: Fan-driven Return Ducts

Unique application “pulls” air across housed equipment in a fully distributed air circulation path, completing the “augmented convective cooling” cycle and optimizing the performance of the heat exchanger. Recirculation with water, coolants and air.
» Read more

Power Panels

Power Panels

Power connections for IT equipment are installed according to customer need. Main power lines are contained in overhead raceways, maintaining segregation of electrical elements and cooling liquid.

Green Profile

Green Profile

Exemplary energy savings. Upgrading racks eliminates need to obsolete Rafts. Accepts IT equipment of varying sizes to accommodate changes in equipment design. Reduces or eliminates need to expand or build out to gain additional data center space.